StatRapid Load Testing

StatRapid Load Testing

StatRapid is a method for Rapid Load Testing: A powerful quasi static test method for determining the static load capacity of piles in compliance with ASTM D7383 and EuroCode 22477

 

Key Characteristics

  • Fast method for high strain pile testing
  • Embodies advantages of SLT and DLT and eliminates disadvantages of these
  • Direct measurement of force and displacements
  • Load-settlement diagram as direct output without a stress wave analysis (no signal matching)
  • Test execution user-independent
  • High accuracy, reliability, and reproducible
  • Fully compliant with international standards (ASTM, EuroCode, etc)

StatRapid is one of the methods of Rapid Load Testing

StatRapid device ready in Down Town Utrecht to perform Rapid Load Testing
StatRapid device ready in Down Town Utrecht to perform Rapid Load Testing

Rapid Load Testing is the method where a pile is loaded in a short moment, giving a gentle push on the pile top. This method is much faster than static load testing. The duration of the load is much longer than during a Dynamic Load Testing (DLT), High Strain Dynamic Testing, or PDA. Due to the long duration of the load, no stress wave phenomena are involved. When the requirements of the quasi-static situation are fulfilled, the interpretation of the Rapid Load Test results is straightforward, without stress wave analysis and without Signal Matching. As a result, the results of Rapid Load Tests are more accurate, reliable, and man-independent.

Rapid Load Testing has two major test methods: StatNamic and StatRapid.

Want to know more about Rapid Load Testing? Contact Joost Bakker at jbakker@allnamics.com

 

StatRapid

StatRapid is the quasi-static, high strain test method for the determination of the bearing capacity of foundation piles. Within the StatRapid test method, a drop weight is dropped on a specially designed StatRapid cushioning. Due to its special characteristics, the kinetic energy of the drop weight is transferred in a relatively long duration push on top of the pile. StatRapid is based on the Rapid Load Testing method, and therefore combines all benefits from Static and Dynamic Testing: A StatRapid Load Test requires limited time, lower costs, and yields high accuracy results.

StatRapid is one of the methods for Rapid Load Testing, here ready to use for the check on the foundation of an onshore wind farm
StatRapid saves time and reduces the influence on the site logistics. A small footprint, and less transport movements

THE STATRAPID TEST DEVICE

The StatRapid device is available with weights of 40 and 80 tonnes and more. Leading to testing load up to 12 and 20 MN and more, depending on the soil and pile conditions.

Each device consists of a basic frame including load cells, the special for Rapid Load Testing designed cushioning, which is modular both in a number of spring elements as in stiffness of each spring element. The upper frame includes the hydraulics for lifting and catching and the test weight. The test weight is also modular. Weight can be added or removed in order to optimize the setup for each pile, depending on soil conditions and on the required test load.

 

ALLWAVE-RLT

The relationship between drop height and test load will be determined prior to the tests, using AllWave-RLT. This program, as part of the AllWave Software Package, simulates the Rapid Load Tests, incorporating all possible influences from the pile, soil, and testing setup.

 

MONITORING SENSORS 

The monitoring system of the StatRapid Load Testing consists of the PDR data acquisition unit and sensors recording the following quantities at the pile top:

  • The load, measured with load cells
  • Displacements with the Allnamics Reyca optical system with a reflector on the pile
  • Accelerations

Direct measurements of loads and settlements give direct measured load-settlement diagrams. By analyzing the results with the Unloading Point Method, according to ASTM and EuroCodes (and other codes), the static load diagram is obtained.

 

SPECIFICATIONS AND CODES

The tests of the Rapid Load Testing are in compliance with a.o. ASTM D7383, and EuroCode EN ISO-22477, as well as other national codes (i.e. Dutch CUR-230). According to these codes:

  • Test data analysis based on user-independent principles,
  • No signal matching is required.
  • Taking into account loading rate dependencies of the soil (as for DLT and PDA)

ADVANTAGES

  • Test data analysis based on user-independent principles,
  • No signal matching is required.
  • Taking into account loading rate dependencies of the soil (as for DLT and PDA)

 

Rapid Load Testing in Hamburg, Germany